FACTS

Safe. The world’s only portable device with Memosens technology for liquid analysis with ATEX approval for measurements up to zone 0/1. Ideal for applications in the process industry.

Robust. The robust and chemical-resistant housing even survives the standardized drop test from 1 meter onto concrete. High-contrast LCD with scratch-proof mineral glass screen can still be read perfectly after many years.

Long-lasting. More than 1,000 hours of measurement are possible with one set of batteries (4xAA).

Communicative. Data logger entries can be shown on the display using an extensive recorder function. The standard micro USB interface enables:

  • connection to a PC
  • software updates

The data logger records up to 10,000 values.
The included Paraly SW 112 software enables easy management of recorded values.

CONDUCTIVITY SENSORS – ANALOG

CODE DESCRIPTION
SE 202 2-electrode sensor with stainless steel body incl. flow cell
SE 204 4-electrode sensor with epoxy body
ZU 6985 4-electrode sensor with glass body (ZU 0290 adapter required)
ZU 0290 Adapter for SE 6985 4-electrode sensor

CONDUCTIVITY SENSORS – DIGITAL

CODE DESCRIPTION
SE 615/1-MS 2-electrode sensor with polymer body
CA/MS-001XFA-L Measuring cable for digital sensors with Memosens connector
CA/MS-003XFA-L Measuring cable for digital sensors with Memosens connector

ACCESSORIES

CODE DESCRIPTION
ZU 0929 Sensor quiver for leak-proof storage
ZU 0925 Li-ion battery (USB chargeable, for Portavo 904, 907 and 908 only)
ZU 0934 Field case for meter and sensor
ZU 0180 Replacement KPG tube for ZU 6985 4-electrode sensor, incl. O-ring
ZU 0284 Replacement flow cell for SE 202 2-electrode sensor
ZU 0289 Adapter for connecting a 2-pole banana plug
ZU 0290 Adapter for connecting the ZU 6985 4-electrode sensor
ZU 6959 Pt1000 temperature probe
CA/M12-001M8-L Measuring cable for digital toroidal conductivity sensors with Memosens protocol

CALIBRATION SOLUTIONS

CODE DESCRIPTION
ZU 6945 Conductivity standard (1 ampoule for producing 0.1 mol/l NaCl solution) 1 ampoule
CS-C013K/250 Conductivity standard 1.3 µS/cm, KCl 250 ml
CS-C15K/500 Conductivity standard 15 µS/cm, KCl 500 ml
CS-C147K/500 Conductivity standard 147 µS/cm, KCl 500 ml
CS-C1413K/500 Conductivity standard 1413 µS/cm, KCl 500 ml
CS-C12880K/500 Conductivity standard 12.88 mS/cm, KCl 500 ml

SE 204 CONDUCTIVITY SENSOR

PROBE SE204

Laboratory conductivity sensor with 4 electrodes, graphite electrode material, epoxy body material.

FACTS

  • Body diameter: 15.3 mm
  • Body length: 120 mm
  • Immersion depth: 36 … 120 mm
  • Operating range: 1 µS/cm … 500 mS/cm
  • Pressure resistance: 2 bar
  • Integrated temperature sensor: NTC 30 Kohm/25 °C
  • Operating temperature range: -5 … 100 °C

SE 204 CONDUCTIVITY SENSOR

PROBE SE204

Laboratory conductivity sensor with 4 electrodes, graphite electrode material, epoxy body material.

FACTS

  • Body diameter: 15.3 mm
  • Body length: 120 mm
  • Immersion depth: 36 … 120 mm
  • Operating range: 1 µS/cm … 500 mS/cm
  • Pressure resistance: 2 bar
  • Integrated temperature sensor: NTC 30 Kohm/25 °C
  • Operating temperature range: -5 … 100 °C

SE 615 N CONDUCTIVITY SENSOR DIGITAL

PROBE SE615

Large measuring range thanks to electrodes made from low polarized special graphite. Designed for MemoRail applications.
The SE 615 conductivity sensor with Memosens connector system has 2 graphite electrodes and requires low maintenance.

The integrated temperature detector provides automatic temperature compensation during calibration and operation of the sensor. The sensor is designed for simultaneous measurement of conductivity and temperature in industrial processes.

FACTS

  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics
  • low maintenance
  • Integrated temperature detector
  • 2 graphite electrodes 

Applications
Water/wastewater treatment.