703 CONDUCTIVITY METER
FACTS
- Measuring ranges from 0.000 µS/cm to 2000 mS/cm
- 1.000 µS/cm … >1000 mS/cm with one sensor
- Records for QM documentation according to ISO 9000 and GLP
- Calibrated analog recorder output, galvanically isolated
- Sensoface: monitoring of the sensor and equipment
- Automatic calibration with standard solutions
- EMC according to NAMUR
- RS-232 interface for computer and printer
- Simultaneous display of two measurement values
- Self-contained clock
- Leak-proof membrane keyboard
- Robust housing
- Protection category IP 54
- 3-year warranty
CONDUCTIVITY SENSORS | |
CODE | DESCRIPTION |
SE 202 | 2-electrode sensor with s/steel body incl. flow cell ZU 0298 adapter required |
SE 204 | 4-electrode sensor with epoxy body ZU 0298 adapter required |
ZU 6985 | 4-electrode sensor with glass body |
ACCERSSORIES | |
CODE | DESCRIPTION |
ZU 6959 | Pt1000 temperature detector |
ZU 0180 | KPG tube for ZU 6985 4-electrode sensor, incl. O-ring |
ZU 0284 | Replacement flow cell for SE 202 2-electrode sensor |
ZU 0298 | Adapter for connecting the SE 202 and SE 204 sensors to the 703 Laboratory Conductivity Meter |
ZU 6954 | Attachable stand for ZU 6955 immersion stirrer and three sensors, directly connected to the meter |
ZU 6955 | Immersion stirrer (powered via ZU 6956 AC adapter) |
ZU 6956 | AC adapter plug for immersion stirrer |
ZU 6959 | Pt 1000 temperature detector |
ZU 0152 | Interface cable for meter – computer connection |
ZU 0245 | Interface cable for meter – printer connection |
ZU 0244 | Lab printer |
ZU 0249 | Printer paper for ZU 0244 lab printer |
ZU 0250 | Ink ribbon for ZU 0244 laboratory printer |
CONDUCTIVITY SOLUTIONS | |
CODE | DESCRIPTION |
ZU 6945 | Conductivity standard (concentrate for preparing 1000 ml of a 0.1 mol/l NaCl solution) |
ZU 0348 | Conductivity standard 12.88 mS/cm (0.1 mol/l KCl) |
ZU 0349 | Conductivity standard 1413 µS/cm (0.01 mol/l KCl) |
ZU 0350 | Conductivity standard 15 µS/cm |
ZU 0702 | Conductivity standard 147 µS/cm |
SE 202 CONDUCTIVITY SENSOR
Laboratory conductivity sensor with 2 electrodes, electrode and body material 1.4571 stainless steel, connector head POM.
FACTS
- Body diameter 12 mm
- Body length 120 mm
- Immersion depth 30 … 120 mm
- Operating range 0.01 … 199.9 µS/cm
- Pressure resistance:
SE 202: 2 bar
SE 202 MS: 1 bar - Integrated temperature sensor NTC 30 KOhm/25 °C
- Operating temperature range:
SE 202: -5 … 100 °C
SE 202 MS: -5 … + 80 °C
SE 204 CONDUCTIVITY SENSOR
Laboratory conductivity sensor with 4 electrodes, graphite electrode material, epoxy body material.
FACTS
- Body diameter: 15.3 mm
- Body length: 120 mm
- Immersion depth: 36 … 120 mm
- Operating range: 1 µS/cm … 500 mS/cm
- Pressure resistance: 2 bar
- Integrated temperature sensor: NTC 30 Kohm/25 °C
- Operating temperature range: -5 … 100 °C